Poster | ASN Kidney Week 2025 | Houston, TX

The Advantages of Low-Voltage Electron Microscopy (LVEM) for Clinical Nephropathology

Daniela Vieira, Emad Shahnam, Jared Lapkovsky

Delong America, Montreal, QC, Canada

Presented at ASN Kidney Week 2025, this poster shows how the LVEM 25E resolves the ultrastructural hallmarks of common kidney diseases at 15 and 25 kV, offering clinical labs an in-house alternative to sending biopsies out to a high-voltage TEM facility.

Transmission electron microscopy (TEM) remains essential in nephropathology because it identifies ultrastructural abnormalities at nanometer-scale resolution. TEM can confidently resolve roughly 90% of cases in which light microscopy is limited by minimal pathological change, and a large body of literature describes the ultrastructural signature of each disease.

Conventional high-voltage TEM (HV-TEM) systems operate at 80 kV or more. They produce detailed images of renal cells, yet their complexity, acquisition and support costs, and low intrinsic contrast without heavy-metal staining have pushed many clinics to give up the capability. Kidney biopsy EM is now concentrated in a limited number of major centers, regardless of local need.

Low-voltage electron microscopy (LVEM) is designed to remove those barriers. LVEM systems are simple to operate and maintain, cost less to acquire and run, and generate higher image contrast, which makes post-staining optional. Their design also allows for compact, robust instruments that fit in a standard laboratory.

Key findings

  • Diagnostic ultrastructure of lupus glomerulonephritis, Alport syndrome, Fabry disease, amyloidosis and podocytopathies resolved on the LVEM 25E.
  • Imaging performed at 15 kV and 25 kV on standard ~80 nm thin sections lightly post-stained with 0.5% uranyl acetate.
  • LVEM 25E resolution of 1.0 nm is sufficient for routine clinical ultrastructural evaluation of renal tissue.
  • Builds on the clinical validation by Lawrence et al. (2020), which found LVEM findings comparable to an 80 kV HV-TEM.

Methodology

TEM images of diseased renal cells were collected with the Delong Instruments LVEM 25E at accelerating voltages of 15 kV and 25 kV. Thin sections (~80 nm) were prepared following standard fixation, sectioning and post-staining protocols, using a reduced 0.5% uranyl acetate stain, and mounted on standard 3 mm copper grids.

LVEM Images of Kidney Thin Sections

LVEM 25E TEM image of fingerprint-like deposits in lupus glomerulonephritis

Fig A. Fingerprint-like deposits typical of lupus glomerulonephritis.

LVEM 25E TEM image of irregular glomerular basement membrane in Alport syndrome

Fig B. Irregular glomerular basement membrane associated with Alport syndrome.

LVEM 25E TEM image of amyloid fibrils in renal tissue

Fig C. Amyloid fibril deposits in affected renal tissue.

LVEM 25E TEM image of damaged podocytes and foot processes

Fig D. Damaged podocytes typical of podocytopathies.

Images acquired with the LVEM 25E at 15 kV and 25 kV.

Results and Discussion

The LVEM 25E delivered enhanced contrast across all specimens, and the expected abnormal features were readily identified in each disease state: fingerprint-like deposits in lupus glomerulonephritis, irregular glomerular basement membranes in Alport syndrome, zebra bodies characteristic of Fabry disease, amyloid fibril deposits, dense deposits, and damaged podocytes typical of podocytopathies.

These observations agree with the clinical validation of LVEM for ultrastructural evaluation of kidney biopsies (Lawrence et al., 2020), in which LVEM produced findings comparable to an 80 kV HV-TEM and preserved the ability to discriminate key diagnostic features. Together, the results support LVEM as a practical alternative to HV-TEM for investigating a broad range of nephropathologies.

Accessibility and Flexibility of LVEM Systems

The LVEM 25E and HV-TEM share the same goal of imaging nanostructures, but they differ sharply in cost and complexity. HV-TEM remains the right tool for atomic-level work such as metallurgy and crystallography. For biological and organic specimens, the high contrast of the LVEM 25E, combined with its affordability, compact footprint and simple maintenance, brings renal ultrastructure back into the clinical laboratory.

Conventional HV-TEM workflow

  1. Collect biopsy sample
  2. Toxic heavy-metal sample preparation
  3. Ship to a third-party facility to generate images

Costly, time-consuming and complicated

LVEM 25E workflow

  1. Collect biopsy sample
  2. Flexible, optional staining
  3. Image and analyze in your own lab

Cost effective, faster turnaround, quick and easy

Researchers operating an LVEM 25E in a laboratory
LVEM 25E installed in a standard laboratory environment

The LVEM 25E installed in the laboratory, highlighting its compact footprint and easy integration into standard lab environments.

Conclusion

The LVEM 25E is a promising alternative to conventional HV-TEM for diagnostic and research work in clinical nephropathology, and for biological thin sections in general. Operating at 25 kV and below, it combines enhanced image contrast with simpler, more compact equipment, while its 1.0 nm resolution meets the needs of clinical ultrastructural studies of renal and other tissue specimens. As the technology continues to advance, LVEM is positioned to play a growing role in diagnostic nephropathology as a cost-effective imaging solution.

Presented at

ASN Kidney Week 2025

American Society of Nephrology | November 6 to 8, 2025 | Houston, TX

Book a Demo

References

  1. Wang G, et al. Optimizing preparation of renal biopsy specimens for TEM: a time-efficient approach to rapid diagnosis of kidney diseases. Renal Failure. 2025;47(1):2522325.
  2. Sementilli A, Moura LA, Franco MF. The role of electron microscopy for the diagnosis of glomerulopathies. Sao Paulo Medical Journal. 2004;122:104-109.
  3. Gunning WT, Calomeni EP. A brief review of transmission electron microscopy and applications in pathology. Journal of Histotechnology. 2000;23(3):237-246.
  4. Vieira D, et al. Low-Voltage Electron Microscopy (LVEM): Part I, Benchtop and Compact TEMs with Heightened Contrast for Soft Materials. Microscopy Today. 2025;33(4):17-20. doi:10.1093/mictod/qaaf048
  5. Lawrence R, et al. Clinical Validation of Low-Voltage "Compact" Transmission Electron Microscopy for Ultrastructural Evaluation of Kidney and Heart Biopsy Samples. Laboratory Investigation. 2020;100(Suppl 1):1701-1702.

Get the full poster

Free PDF, sent straight to your inbox. Four quick details and it is on its way.

ASN Kidney Week 2025 poster: The advantages of LVEM for clinical nephropathology
Please enter your first name

Please enter your last name

Please enter a valid phone number

Please enter a valid email address

Please enter an institution name.