Poster | Biophysical Society 2026 | San Francisco, CA

Low-Voltage Electron Microscopy: An Emerging Alternative to HV-TEM for the Structural Characterization of Proteins

Daniela Vieira, Emad Shahnam, Jared Lapkovsky

Delong America, Montreal, QC, Canada

Presented at the Biophysical Society 70th Annual Meeting, this poster shows negatively stained proteins and virus-like particles imaged on the LVEM 25E at 25 kV, with morphology consistent with high-voltage TEM and markedly higher image contrast.

Electron microscopy is an indispensable tool for characterizing biological specimens, and its nanometer-scale view of structure makes it essential for studying proteins. Transmission electron microscopy (TEM) and cryo-TEM are the most widely used approaches.

High-voltage TEM (HV-TEM), operating at 80 kV or more, provides detailed images of proteins but suffers from low intrinsic image contrast and high operating cost and complexity. Cryo-TEM delivers the highest level of structural detail, yet instrument access is narrow and sample preparation and data acquisition are increasingly demanding.

Low-voltage electron microscopy (LVEM), operating below 25 kV, addresses these challenges. It allows evaluation of particle integrity, distribution and homogeneity comparable to HV-TEM data, and has proven useful as a screening step before cryo-TEM, so samples can be optimized quickly before freezing. All of this comes with simpler instruments, simpler sample preparation and easier operation.

Key findings

  • Virus-like particles, SERCA, a 700 kDa protein and proteasomes were all clearly resolved on the LVEM 25E at 25 kV.
  • Protein morphology was well preserved, with delineation consistent with HV-TEM images of the same samples.
  • Image contrast improved by up to 20-fold compared with HV-TEM, giving more flexibility in staining procedures.
  • LVEM serves as an in-lab screening tool ahead of cryo-TEM, with lower facility and operating requirements.

Methodology

TEM images of a range of negatively stained proteins and virus-like particles (VLPs) were acquired with a low-voltage TEM operating at 25 kV (LVEM 25E, Delong Instruments). Samples were deposited on standard 3 mm TEM grids, and the resulting images were compared with HV-TEM data of the same specimens. VLP samples were provided by the New York Structural Biology Center (NYSBC).

LVEM Images of Proteins

LVEM 25E negative stain TEM images of virus-like particles, SERCA protein, a 700 kDa protein and proteasomes

Fig A. Virus-like particles, SERCA protein, a 700 kDa protein and proteasomes imaged on the LVEM 25E at 25 kV.

Side by side comparison of virus-like particles imaged by LVEM and by HV-TEM

Fig B. The same virus-like particle sample imaged by LVEM (left) and HV-TEM (right).

LVEM images acquired with the LVEM 25E at 25 kV.

Results and Discussion

Across all samples, LVEM images showed sufficient resolution together with enhanced contrast, allowing clear identification and characterization of protein morphology and structure. Morphology was well preserved and delineation was consistent with that observed in HV-TEM images.

In the direct comparison, LVEM images showed clearly superior contrast to HV-TEM. This follows from the lower accelerating voltage, which increases electron scattering and consequently raises image contrast. The practical benefit is improved visualization and greater flexibility in staining procedures.

Accessibility and Flexibility of LVEM

LVEM and HV-TEM share the goal of imaging nanostructures but differ sharply in cost and complexity. HV-TEM remains the right choice for atomic-level work such as metallurgy and crystallography, while the high contrast of LVEM makes it particularly well suited to biological and organic materials.

HV-TEM

  1. Low contrast: negative staining is mandatory
  2. Complex design: special facility, anti-vibration platform and cooling system required
  3. High investment in installation, operation and maintenance

Powerful but costly and centralized

LVEM 25E

  1. Up to 20-fold higher contrast and flexible staining
  2. In-lab instrument with a compact design and simple operation
  3. Low installation, operation and maintenance costs

Accessible protein imaging in your own lab

Researchers operating an LVEM 25E in a laboratory
LVEM 25E installed in a standard laboratory environment

The LVEM 25E installed in the laboratory, highlighting its compact footprint and easy integration into standard lab environments.

Conclusion

Operating at 25 kV, LVEM offers an accessible and practical solution for biological research, providing data comparable to HV-TEM while improving image contrast by up to 20-fold. As an in-lab instrument it requires simpler facility infrastructure and carries lower maintenance and operating costs, and it has shown strong accessibility and effectiveness for negative-stain protein imaging.

Presented at

Biophysical Society 70th Annual Meeting

Booth 633 | February 21 to 25, 2026 | San Francisco, CA

Book a Demo

References

  1. Nogales E, Scheres SHW. Cryo-EM: a unique tool for the visualization of macromolecular complexity. Molecular Cell. 2015;58(4):677-689.
  2. Weissenberger G, Henderikx RJM, Peters PJ. Understanding the invisible hands of sample preparation for cryo-EM. Nature Methods. 2021;18(5):463-471.
  3. Möller L, Holland G, Laue M. Diagnostic electron microscopy of viruses with low-voltage electron microscopes. Journal of Histochemistry & Cytochemistry. 2020;68(6):389-402.
  4. Vieira D, et al. Unlocking new potential in bio-TEM: the impact of low voltage electron microscopy and alternative staining methods. Microscopy and Microanalysis. 2025;31(Suppl 1):ozaf048.410.
  5. Ausman KD, et al. Low voltage electron microscopy: an emerging tool for AAV characterization. Journal of Pharmaceutical Sciences. 2025;114(3):1554-1562.

Get the full poster

Free PDF, sent straight to your inbox. Four quick details and it is on its way.

Biophysical Society 2026 poster: Low voltage electron microscopy, an emerging alternative to HV-TEM for the structural characterization of proteins
Please enter your first name

Please enter your last name

Please enter a valid phone number

Please enter a valid email address

Please enter an institution name.