Poster | CNSP-RCPS SPM 2026 | Ottawa, ON

Benefits of Low Voltage Electron Microscopy for Scientific Cores

Jared Lapkovsky

Delong America, Montreal, QC, Canada

Presented at the CNSP-RCPS 2026 Scientific Platform Meeting in Ottawa, this poster outlines how low voltage electron microscopy (LVEM) helps scientific core facilities expand electron microscopy access without the infrastructure, staffing and staining burden of conventional TEM.

Scientific core facilities are increasingly challenged to provide high-quality electron microscopy access while managing rising infrastructure, maintenance and staffing demands. Conventional high-voltage TEM (HV-TEM) systems operating at 80 to 120 kV require dedicated facilities with anti-vibration platforms, liquid cooling and on-site technical expertise, which creates significant barriers to routine access [1]. Heavy-metal staining protocols (uranyl acetate, lead citrate) introduce radioactive and carcinogenic hazards, further limiting usability in shared environments [2].

LVEM offers a compelling alternative. Operating at 5 to 25 kV with compact permanent magnet optics and an air-cooled design, LVEM systems can be installed directly within departmental or shared laboratories without dedicated facility infrastructure. Enhanced intrinsic image contrast for carbon-rich, biological and polymeric specimens reduces or eliminates reliance on heavy-metal staining [3]. The poster highlights the benefits of integrating the LVEM 5 and LVEM 25E into core facilities supporting life sciences, materials science, pathology, nanotechnology and education.

Key findings

  • LVEM systems run from a standard 120 V outlet in ordinary lab space, with no liquid cooling, anti-vibration platform or shielded EM suite.
  • Signal-to-noise on biological specimens improves approximately 8 to 10× over conventional 80 kV HV-TEM, enabling reliable interpretation of unstained or minimally stained samples [4].
  • One platform covers nanoparticles, extracellular vesicles, thin-section pathology, virology and teaching.
  • Rapid negative stain screening on the LVEM helps cores decide which samples are ready for high-demand cryo-EM sessions.

Two LVEM Platforms for the Core

The LVEM 5 is a benchtop electron microscope operating at 5 kV with a field emission source. It offers TEM, SEM, STEM and electron diffraction (ED) modes, with imaging resolutions of 1.2 nm (TEM), 4 nm (SEM) and 2.5 nm (STEM). It needs 62 cm × 100 cm of desk space and a 120 V power outlet, and is operated with manual controls.

The LVEM 25E is a compact electron microscope operating at 10, 15 and 25 kV, also with a field emission source. It adds energy dispersive spectroscopy (EDS) to TEM, SEM, STEM and ED modes, with imaging resolutions of 1.0 nm (TEM), 4 nm (SEM) and 1.0 nm (STEM). It occupies 74 cm × 200 cm of floor space, runs from a 120 V outlet and includes integrated automation for very easy operation.

Representative LVEM Micrographs

LVEM TEM image of a kidney thin section

Fig A. Kidney thin section.

LVEM TEM image of virus particles in a thin section

Fig B. Virus thin section.

LVEM TEM image of negatively stained adeno-associated virus (AAV) particles

Fig C. Negative stain adeno-associated virus (AAV) particles.

LVEM TEM image of unstained carbon nanotubes

Fig D. Carbon nanotubes imaged without staining.

Representative LVEM micrographs of biological specimens and nanomaterials from the poster.

Applications in the Core Facility

LVEM platforms support a broad range of core applications. Nanoparticle characterization (gold, polymeric and mixed systems) is performed routinely using TEM, STEM and EDS modes. Extracellular vesicles, exosomes and lipid nanoparticles are imaged with high contrast, often without staining. Thin-section pathology workflows on kidney, liver, muscle and brain specimens benefit from enhanced ultrastructural detail for both research and clinical diagnostics [4,5]. Educational and training programs benefit from the simple, accessible format of the LVEM 5.

Enhanced contrast for biological samples. Intrinsic contrast for biological and soft materials gives clear visualization of membranes, organelles, viral particles and polymeric structures without radioactive or carcinogenic heavy-metal stains [2,3].

Routine imaging of nanomaterials. LVEM provides high-contrast imaging of nanoparticles, carbon nanotubes, quantum dots and graphene, including electron diffraction, without staining or specialized facilities [1,2].

Pre-screening for cryo-EM. Researchers can rapidly assess sample quality, particle distribution, grid suitability and staining quality on the LVEM before committing samples to high-demand cryo-EM sessions. No liquid nitrogen is required for routine negative stain screening, and simple sample loading makes the LVEM well suited as a daily-use screening instrument within larger cryo-EM pipelines. This step reduces wasted instrument time and improves facility throughput [1,3].

Accessibility and Flexibility of LVEM

LVEM and HV-TEM differ fundamentally in infrastructure requirements, operating costs and deployment flexibility. LVEM systems are air-cooled, self-contained and can be installed in standard laboratory spaces with minimal preparation. Permanent magnet optics require no routine servicing, and acquisition and operating costs are substantially lower, so core facilities can expand imaging capabilities without major capital investment in facility infrastructure [1,2,3].

Conventional HV-TEM

  1. Requires a dedicated, shielded EM suite
  2. Expert microscopists required
  3. Turnaround of weeks to months
  4. Shared-facility scheduling
  5. Frequent preventative maintenance
  6. Limited contrast for organic materials

High purchase and facility cost

LVEM 5 and LVEM 25E

  1. Benchtop or compact, fits in a standard lab
  2. Intuitive software, minimal training
  3. Same-day results
  4. Immediate, on-demand imaging
  5. No routine maintenance
  6. Enhanced contrast for organic materials

A fraction of the purchase and operating cost

LVEM installed in a teaching laboratory with students at the controls
LVEM installed in a shared research laboratory
Researcher standing beside an LVEM in a laboratory
Researcher standing beside an LVEM in a wet laboratory

Representative LVEM 5 and LVEM 25E installations in a classroom, a clean laboratory, a cryo-sample prep lab and a wet laboratory.

Conclusion

LVEM platforms provide scientific core facilities with a practical, cost-effective pathway to expand electron microscopy access. The combination of enhanced intrinsic contrast, simplified sample preparation, compact footprint and reduced infrastructure requirements enables deployment where conventional HV-TEM is not feasible. The LVEM 5 and LVEM 25E support multi-modal imaging for applications ranging from nanoparticle characterization and biomedical research to clinical pathology and educational training. By lowering the barriers to routine EM access, LVEM platforms help democratize high-resolution imaging across diverse research communities [1,2,3,4].

Presented at

CNSP-RCPS 2026 Scientific Platform Meeting

Canadian Network of Scientific Platforms | June 9 to 11, 2026 | University of Ottawa, Ottawa, ON

Book a Demo

References

  1. Vieira D, Shahnam E, Lapkovsky J, et al. Low-Voltage Electron Microscopy (LVEM): Part I. Benchtop and Compact TEMs with Heightened Contrast for Soft Materials. Microscopy Today. 2025;33(4). Link
  2. Vieira D, Shahnam E, Lapkovsky J, et al. Low-Voltage Electron Microscopy (LVEM): Part II. Applications Where LVEM Provides Significant Benefit. Microscopy Today. 2025;33(6):22-26. Link
  3. Mrazova K, Bacovsky J, Sedrlova Z, et al. Urany-Less Low Voltage Transmission Electron Microscopy: A Powerful Tool for Ultrastructural Studying of Cyanobacterial Cells. Microorganisms. 2023;11(4):888. doi:10.3390/microorganisms11040888
  4. Möller AK, et al. Diagnostic Electron Microscopy of Viruses With Low-voltage Electron Microscopes. Journal of Histochemistry & Cytochemistry. 2020;68(6).
  5. Ausman KD, Whitaker N, Balasubramanian M, Kokona B, Vogt A, Kar SR. Low Voltage Electron Microscopy: An Emerging Tool for AAV Characterization. Journal of Pharmaceutical Sciences. 2025. Link

Get the full poster

Free PDF, sent straight to your inbox. Four quick details and it is on its way.

Preview of the poster Benefits of Low Voltage Electron Microscopy for Scientific Cores
Please enter your first name

Please enter your last name

Please enter a valid phone number

Please enter a valid email address

Please enter an institution name.